Description

Conductivity Bench Meter

These instruments utilize a four ring potentiometric probe with platinum sensor that offers greater versatility over typical amperometric designs. A potentiometric probe works on the principal of induction which eliminates the effects of polarization (a common problem of amperometric systems).

Two outer rings apply an alternating voltage and induce a current loop in the solution while two inner rings measure the voltage drop induced by the current loop (which is dependent on the conductivity of the solution).By utilizing the 4-ring method, it is possible to measure very low or high conductivity levels (up to 200 mS/cm) without changing probes.

The temperature coefficient correction is settable between 0 and 2.5%/ºC for EC 215.

Features Conductivity Bench Meter

  • Four measurement ranges
  • Manual calibration

Automatic Temperature Compensation

HI 2314 and HI 2315 Specifications

EC

Range                                                                               0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm; 0.0 to 199.9 mS/cm

Resolution                                                                       0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm

Accuracy @ 20°C                                                           ±1% F.S. (excluding probe error)

Calibration                                                                       manual, one point

Additional Specifications

HI 2314                                                                           HI 2315

HI 76300, platinum four ring conductivity probe with DIN connector and 1 m (3.3’) cable (included)

HI 76303, platinum four ring conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included)

Temperature Compensation                                    manual, 0 to 50°C (32 to 122°F) with β = 2%/°C                            automatic, 0 to 50°C (32 to 122°F) with β adjustable from 0 to

Power Supply                                                                12 VDC adapter (included)

Environment                                                                  0 to 50°C (32 to 122°F); RH max 95% non-condensing

Dimensions                                                                     235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)

Weight                                                                              1.3 kg (2.9 lbs.)

Ordering Information

HI 2314-01 (115V) and HI 2314-02 (230V) are supplied with HI 76300 conductivity probe, 12 VDC adapter and instruction manual. HI 2315-01 (115V), HI 2315-02 (230V) and HI 2315-03 (AUS plug), are supplied with HI 76303 conductivity probe, 12 VDC adapter and instruction manual.

Additional information

Brand

Categories

Model :

Specifications

Download

Reviews

0.0 Average Rating Rated ( 0 Review )

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%
Submit Review

There are no reviews yet.

Be the first to review “Conductivity Bench Meter”

Your email address will not be published. Required fields are marked *

General Inquiries

There are no inquiries yet.